©2013, KEPCO, INC 1
Data subject to change without notice 228-1703 REV 1
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 "
FAX (718) 767-1102
http://www.kepcopower.com "
email: hq@kepcopower.com
QUICK START GUIDE
KEPCO
An ISO 9001 Company.
HSF
300W
SINGLE OUTPUT 3U
HOT SWAP PLUG-IN POWER SUPPLIES
I — INTRODUCTION
SCOPE OF MANUAL. This Quick Start Guide covers
the installation and operation of the Kepco HSF 300W
Series of Hot Swap Plug-in Power Supplies. Full specifica-
tions are listed in the applicable 300W standard (non-
metered) and 300W metered (M and MZ) HSF Operator
Manual that can be downloaded from the Kepco web site
at:
www.kepcopower.com/support/opmanls.htm#hsf
These power supplies are designed to be installed in
Kepco’s RA 19-4C Rack Adapter. The RA 19-4C Operator
Manual can be downloaded from the Kepco web site at:
www.kepcopower.com/support/opmanls.htm#ra19-4c
FACTORY DEFAULTS. This guide covers only units as
shipped from the factory with the two internal DIP switches
set to default configuration (see Figure 1). For other config-
urations, refer to applicable Operator Manual.
DESCRIPTION. The Kepco HSF 300 Watt Series are hot
swappable, high frequency switching, plug-in power sup-
plies. Models may be selected for outputs of 5V, 12V, 15V,
24V, 28V or 48V. They employ power factor correction and
are designed to operate in a fault tolerant power system
with a nominal a-c input of 100V a-c to 240V a-c (input volt-
age range 85 to 265 Va-c), 50-60 Hz (input frequency
range 47-440Hz). A built-in current balancing circuit and
OR-ing diodes allow configuration for hot-swap and paral-
lel-redundant N+1 operation.
FIGURE 1. DIP SWITCH FACTORY DEFAULTS
OPTIONS. M and MZ models include a digital meter
which displays either voltage or current as determined by a
front panel switch. M Models (except HSF 5-60M) require
a minimum output voltage to power the meter, alarm relay
and VDC ON indicator; MZ models, as well as HSF 5-
60M, can be adjusted down to 0V output without affecting
operation of meter, alarm relay and VDC ON indicator. C
models allow independent current monitoring.
II — INSTALLATION
PRIOR TO MOUNTING. Two internal DIP switches are
preconfigured for the factory defaults listed above. To
change the factory defaults, refer to the applicable operator
manual and configure the DIP switches prior to installation.
KEYING. The units are keyed by voltage at the factory.
Refer to the RA 19-4C Operator Manual to make the rack
adapter slot match the HSF.
MOUNTING THE POWER SUPPLY. Release the two
cap head screw retaining latches (see Figure 2) by loosen-
ing the cap-head screw approximately 1/2 turn CCW (use
5/32" hex key) and slide to open (up) position. Insert power
supply in the slot, then retighten the cap-head screws CW
until snug. DO NOT OVERTIGHTEN! To release, follow the
same procedure, except lift the latch to the top of the slot.
Be sure to move the latch completely up or down to ensure
full engagement/disengagement of the latching mecha-
nism. When HSF is not installed in rack adapter, secure
latch in open (up) position to prevent damage.
CONNECTIONS. All connections are made at the rear
panel of the RA 19-4C Rack Adapter (see RA 19-4C Oper-
ator Manual).
3043515
- FRONT PANEL VADJ CONTROL
- RELAY ALARM SELECTED
- VISUAL ALARM DISABLED
- REMOTE ON-OFF DISABLED
- DC ON PWR BY REF V ENABLED
Factory default settings
for all options
6
6
8
7
7
8
8
8
SW2
SW1
7
7
OFF
6
5
4
3
2
1
2
3
5
4
4
6
5
5
3
4
3
1
1
2
2
1
ON ON
OFF
TAB
TABLE 1. HSF 300W HOT SWAP MODELS
MODELS 5V 12V 15V 24V 28V 48V
300W HSF 5-60 HSF 12-27 HSF 15-22 HSF 24-14 HSF 28-12 HSF 48-7
NOTE: Options include suffix M, MZ or C: M or MZ for meter; C for current monitor.