INSTRUCTION SHEET
KEPCO
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000
FAX (718) 767-1102
http://www.kepcopower.com
An ISO 9001 Company.
CABLE
219-0449
KIT
CABLE KIT NO. 219-0449
BOP 1000W MODELS (2) IN PARALLEL
This kit contains the cables and terminations required to operate two identical 1000 Watt BOP High Power mod-
els in parallel, effectively multiplying the output current capacity by two. Only identical models may be configured
to operate in parallel.
This kit can be used with all 1000W BOP models that have revision levels as shown in Table 1. Earlier models
that have been upgraded to permit multiple unit configurations must include the letter “A” following the revision
number. CAUTION: Failure to install the ground cables supplied can result in damage to the power supply.
Refer to the associated technical manual supplied with the 1000W BOP power supply for all instructions regard-
ing installation and operation of multiple units in parallel.
I. SPECIFICATIONS
Table 3 lists the model parameters unique to a parallel combination of two identical 1000W BOP Power Supplies.
Table 4 lists the general specifications for the parallel combinations listed in Table 3. For specifications not listed
in Table 3, refer to the General Specifications provided in the associated technical manual supplied with each
1000W BOP power supply
TABLE 1. REVISION LEVELS APPLICABLE TO THIS KIT
MG Model Revision
Revisions for previously Upgraded
Units (Must include “A”)
GL Model Revision
BOP 6-125MG All All
BOP 10-75MG 5 or higher 3A or 4A
BOP 20-50MG 8 or higher 5A, 6A or 7A BOP 20-50GL All
BOP 25-40MG All All
BOP 36-28MG 11 or higher 8A, 9A or 10A
BOP 50-20MG 7 or higher 5A or 6A BOP 50-20GL All
BOP 72-14MG 7 or higher 6A
BOP 100-10MG 6 or higher 2A or 4A
TABLE 2. EQUIPMENT SUPPLIED
Item Quantity Purpose
Kepco Part
Number
Common power cable **
(1.5 ft.)
1
Connects the COMMON terminal of the Master to the COMMON terminal of the
Slave #1.
118-1129
Output Power cable
(1.5 ft.)
1
Connects the OUTPUT terminal of the Master to the OUTPUT terminal of the
Slave #1.
118-1112
Digital Control (Bitbus)
Cable ** (1.5 ft.)
1
Provides communication between master and slave. 118-1108
Parallel Control Cable
(1.5 ft.)
1
Provides control signals required for parallel operation. 118-1119
Protection Cable
(1 ft.)
1
Provides interlock protection signals required for multiple unit operation. 118-1126
Master - IN Parallel Control
Termination
1 Provides proper termination for Parallel Control Cable. 195-0109
** For GL units: Unclamp and remove ferrite from cable before installation.
!
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - INSTRUCTION SHEET

©2012, KEPCO, INCData subject to change without notice228-1485 REV 7 051812INSTRUCTION SHEETKEPCOKEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, N

Seite 2 - II. SPECIFICATIONS

KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A.  TEL (718) 461-7000 FAX (718) 767-1102  email: [email protected] 228-148

Kommentare zu diesen Handbüchern

Keine Kommentare